Railway Power Solutions - Flipbook - Page 15
RAILWAy DC/DC CoNVERTERS (PCB MoUNTINg)
5.3 (0.21)
| 40 W
36.8 (1.45)
4x 3.81 10.8
(4x 0.15)
(0.43)
3.6 (0.14)
TEP 40UIR
12.7
(0.50)
under voltage lockout
3-year product warranty
TEN 60WIR
50.8
Bottom view
57.9
12:1 input voltage range
· Ultra-wide
9–75, 14–160 VDC
Compact 2.3" × 1.45" × 0.5"
· standard
package (quarter brick)
Bus
pin
to
easily extend hold-up time
·
50155 and EN 61373 approval
· EN
for railway applications
cation for fire behavior according
· Qualifi
to EN 45545-2
temperature range
· Operating
–40°C to +85°C
· I/O-isolation 3000 VAC
· High efficiency up to 91%
output voltage,
· Adjustable
Remote On/Off and adjustable
47.24 (1.86)
(2.28)
Screw
2x M3x0.5
(2.00)
3 10 2 9 1
·
Model
TEP 40-3611UIR
TEP 40-3612UIR
TEP 40-3613UIR
TEP 40-3615UIR
TEP 40-3618UIR
TEP 40-7211UIR
TEP 40-7212UIR
TEP 40-7213UIR
TEP 40-7215UIR
TEP 40-7218UIR
Input
Voltage
Range
9–75 VDC
(36 VDC nom.)
14–160 VDC
(110 VDC nom.)
Output
Vnom
Imax
5VDC
12 VDC
15 VDC
24 VDC
48 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
8A
3.33 A
2.67 A
1.67 A
0.83 A
8A
3.33 A
2.67 A
1.67 A
0.83 A
Efficiency
89%
91%
91%
90%
91%
89%
91%
91%
90%
90%
8 76 5 4
5.1
4x 3.81
5.3
(4x 0.15)
(0.21)
(0.2)
26.16 (1.03)
Pin (4, 8): 1.5 (0.06)
Pin (other): 1.0 (0.04)
Pin diameter ±0.1 (±0.004)
Screw lock torque: Max. 0.34 N·m (3.5 kgf·cm)
Pin Connection
Pin
Function
Diameter
1
–Vin
0.04 Inch
2
Remote on/off
0.04 Inch
3
+Vin
0.04 Inch
4
–Vout
0.06 Inch
5
–Sense
0.04 Inch
0.04 Inch
6
Trim
7
+Sense
0.04 Inch
8
+Vout
0.06 Inch
9
Bus
0.04 Inch
10
UVLo
0.04 Inch
| 60 W
Model
25.4
(0.40)
(1.00)
(0.5)
(0.2)
40.64 (1.60)
45.72 (1.80)
(2.00)
3
2 1
7
33.0 (1.30)
50.8
Bottom View
6
10.16
8
4
5
7.62
(0.4)
2.7
5.08 12.7
(0.4)
(0.11)
(0.95)
(0.10)
24.10
10.16
Compact 2" × 1" package
(without heatsink)
Wide 4:1 input voltage range:
9–36, 18–75, 36–160 VDC
EN 50155 and EN 61373 approval for
railway applications
Qualification for fire behavior according
to EN 45545-2
Operating temperature range
–40°C to +85°C
I/O-isolation 3000 VDC
High efficiency up to 92%
Under voltage lock out circuit
Adjustable output voltage and
Remote On/Off
3-year product warranty
10.2
Front View
2.55
(1.00 max.)
25.4 max.
40.7 (1.60)
·
·
·
·
·
·
·
·
·
·
PAgE 15
2.54
(0.1)
(0.3)
Pinout
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (gND)
–Vin (gND)
3
Remote on/of
Remote on/of
4
+Vout
+Vout
5
–Vout
Common
6
Trim
–Vout
7
Heatsink
8
Heatsink
TEN 60-2411WIR
TEN 60-2412WIR
TEN 60-2413WIR
TEN 60-2415WIR
TEN 60-2418WIR
TEN 60-2422WIR
TEN 60-2423WIR
TEN 60-2425WIR
TEN 60-4811WIR
TEN 60-4812WIR
TEN 60-4813WIR
TEN 60-4815WIR
TEN 60-4818WIR
TEN 60-4822WIR
TEN 60-4823WIR
TEN 60-4825WIR
TEN 60-7211WIR
TEN 60-7212WIR
TEN 60-7213WIR
TEN 60-7215WIR
TEN 60-7218WIR
TEN 60-7222WIR
TEN 60-7223WIR
TEN 60-7225WIR
Input
Voltage
Range
9–36 VDC
(24 VDC nom.)
18–75 VDC
(48 VDC nom.)
36–160 VDC
(110 VDC nom.)
Output
Vnom
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
±12 VDC
±15 VDC
±24 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
±12 VDC
±15 VDC
±24 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
±12 VDC
±15 VDC
±24 VDC
Imax
12 A
5A
4A
2.5 A
1.25 A
±2.5 A
±2 A
±1.25 A
12 A
5A
4A
2.5 A
1.25 A
±2.5 A
±2 A
±1.25 A
12 A
5A
4A
2.5 A
1.25 A
±2.5 A
±2 A
±1.25 A
Efficiency
91%
93%
93%
91%
92%
91%
91%
92%
92%
93%
94%
92%
92%
92%
92%
92%
91%
92%
92%
91%
91%
91%
91%
91%