Railway Power Solutions - Flipbook - Page 25
RAILWAy DC/DC CoNVERTERS (oFF-BoARD MoUNTINg)
TEP 150WI
PAgE 25
| 150 W
52.5
(2.07)
35.7
(1.6)
Model
TEP 150-2412WI
TEP 150-2413WI
TEP 150-2415WI
TEP 150-2416WI
TEP 150-2418WI
TEP 150-4812WI
TEP 150-4813WI
TEP 150-4815WI
TEP 150-4816WI
TEP 150-4818WI
TEP 150-7212WI
TEP 150-7213WI
TEP 150-7215WI
TEP 150-7216WI
TEP 150-7218WI
65.0
(2.56)
59.0
(2.32)
TEQ 160WIR
(3.86)
18–75 VDC
(48 VDC nom.)
43–160 VDC
(110 VDC nom.)
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
Imax
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
Efficiency
86%
86%
87%
87%
86%
88%
89%
89%
89%
88%
88%
89%
89%
89%
88%
98.0
56.0
metal case with screw
· Shielded
terminals
wide 4:1 input voltage ranges
· Ultra
9–36, 18–75, 43–160 VDC
50155 approval for railway
· EN
applications
· Very high efficiency up to 89%
current output characteristic
· Constant
for battery load applications
with input filter to meet
· Optional
EN 55032 class B
Operating temperature range:
· Wide
–40°C to +75°C
voltage lock-out &
· Under
overtemperature protection
· Easy chassis and wall mounting
· 3-year product warranty
9–36 VDC
(24 VDC nom.)
Output
Vnom
(2.20)
21.0
(0.83)
1.2 (0.05)
1 2 3 4 5 6 7 8 9
Input
Voltage
Range
4 x r2
(0.08)
Pinout
Pin
Function
1
+Vin
Recommended Wire
14–16 AWg
2
+Vin
14–16 AWg
3
–Vin
14–16 AWg
4
–Vin
14–16 AWg
5
Remote
14–24 AWg
14–16 AWg
6
+Vout
7
–Vout
14–16 AWg
8
Trim
14–24 AWg
9
Trim
14–24 AWg
| 160 W
103.2 (4.06)
74.2 (2.92)
Output
ON LED
1
2
3
4
5
6
19–75 VDC
(48 VDC nom.)
43–160 VDC
(110 VDC
nom.)
Imax
12 VDC
24 VDC
28 VDC
48 VDC
12 VDC
24 VDC
28 VDC
48 VDC
13’000 mA
6500 mA
5500 mA
3200 mA
15’000 mA
7500 mA
6500 mA
3800 mA
Efficiency
90%
90%
90%
90%
89%
89%
89%
89%
76.2 (3.00)
power block with excellent thermal
· High
convection
temperature
· Operating
–40°C to +75°C without derating
· Increased shock & vibration resistance
· Ultra wide 4:1 input voltage range
50155 approval for railway
· EN
applications
· Excellent efficiency up to 90%
· Input filter meet EN 55022, class A
· I/O insulation 1591 VAC
· Under voltage lock-out circuit
· 3-year product warranty
TEQ 160-4812WIR
TEQ 160-4815WIR
TEQ 160-4816WIR
TEQ 160-4818WIR
TEQ 160-7212WIR
TEQ 160-7215WIR
TEQ 160-7216WIR
TEQ 160-7218WIR
Output
Vnom
Output voltage adjust
Screw 4–M3X0.5
87.6 (3.45)
88.9 (3.50)
3.2 (0.13)
7
8
9
10
11
12
79.1 (3.114)
TOP VIEW
Model
Input
Voltage
Range
Pinout
Terminal Pin Function
Recommended Wire
1, 2
–Vin
3
NC
12 AWg
NC
4
on/off Ctrl
14–18 AWg
5, 6
+Vin
12 AWg
7, 8
–Vout
12 AWg
9
–Sense*
14–18 AWg
10
+Sense*
14–18 AWg
11, 12
+Vout
12 AWg
* Sense line to be connected to the output either at the module or at the
load under regard of polarity.
– The current rating of the terminal block is 15 A/pole.
– Using 2 poles in parallel if the peak output current can exceed 15 A.
– Wire size shall be selected to withstand the peak output current (Iout
max + Current limitation).