RAILWAY DC/DC CONVERTERS (PCB MOUNTING)
TEP 160WIR
160 Watt
5
1
Model
4.8 (0.19)
Pin diameter pins 5 & 9: 2.0 (0.08)
Pin diameter other pins: 1.0 (0.04)
25.4 (1.0)
(0.3)
7.62
97
8
screw1
4× M3x0.5
(trough hole)
48.26 (1.9)
17.78 (0.7)
6
10
4
3
61.0 (2.4)
50.80 (2.0)
2
Bottom view
Input Voltage
Range
TEP 160-2412WIR
TEP 160-2413WIR
9 – 36 VDC
TEP 160-2415WIR
(24 VDC nom.)
TEP 160-2416WIR
TEP 160-2418WIR
TEP 160-4812WIR
TEP 160-4813WIR
18 – 75 VDC
TEP 160-4815WIR
(48 VDC nom.)
TEP 160-4816WIR
TEP 160-4818WIR
TEP 160-7212WIR
TEP 160-7213WIR
43 – 160 VDC
TEP 160-7215WIR
(110 VDC nom.)
TEP 160-7216WIR
TEP 160-7218WIR
Output
Vnom
Imax
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12’000 mA
9500 mA
6000 mA
5000 mA
3000 mA
13’000 mA
10’000 mA
6500 mA
5500 mA
3200 mA
15’000 mA
12’000 mA
7500 mA
6500 mA
3800 mA
Efficiency
90%
91%
90%
90%
90%
91%
91%
91%
91%
91%
90%
90%
90%
90%
90%
(0.5)
(0.023)
12.7
0.6
5.1
¡ Compact metal package
¡ Ultra wide 4:1 input voltage ranges
9–36, 18–75, 43–160 VDC
¡ EN 50155 approval for railway
applications
¡ Very high efficiency up to 91%
¡ No minimum load
¡ Soft start
¡ Ajustable output voltage +10/-20%
¡ Sense line
¡ Remote On/Off input
¡ Under voltage lock-out circuit
(0.2)
57.9 (2.28)
Pinout
Pin
1
Function
Pin Diameter
–Vin (GND)
1 mm (0.04)
2
Case
1 mm (0.04)
3
Remote
1 mm (0.04)
4
+Vin (Vcc)
1 mm (0.04)
5
–Vout
2 mm (0.08)
6
–Sense
1 mm (0.04)
7
Trim
1 mm (0.04)
8
+Sense
1 mm (0.04)
9
+Vout
2 mm (0.08)
10
Sync (on demand)
1 mm (0.04)
TEP 200WIR
200 Watt
Model
Input Voltage
Range
TEP 200-2412WIR
TEP 200-2413WIR
9 – 36 VDC
TEP 200-2415WIR
(24 VDC nom.)
TEP 200-2416WIR
TEP 200-2418WIR
TEP 200-4812WIR
TEP 200-4813WIR
18 – 75 VDC
TEP 200-4815WIR
(48 VDC nom.)
TEP 200-4816WIR
TEP 200-4818WIR
TEP 200-7212WIR
TEP 200-7213WIR
43 – 160 VDC
TEP 200-7215WIR
(110 VDC nom.)
TEP 200-7216WIR
TEP 200-7218WIR
¡ Compact metal package
¡ Ultra wide 4:1 input voltage ranges
9–36, 18–75, 43–160 VDC
¡ EN 50155 approval for railway
applications
¡ Very high efficiency up to 91%
¡ No minimum load
¡ Soft start
¡ Under voltage lock-out circuit
¡ Ajustable output voltage +10 / –20%
¡ Sense line
Pinout
Pin
1
Function
–Vin (GND)
2
NC
3
Remote
4
+Vin (Vcc)
5
–Vout
6
–Sense
7
Trim
8
+Sense
9
+Vout
Output
Vnom
Imax
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
15’000 mA
12’000 mA
7500 mA
6500 mA
3700 mA
18’000 mA
14’000 mA
9000 mA
7500 mA
4500 mA
20’000 mA
16’000 mA
10’000 mA
8500 mA
5000 mA
Efficiency
89%
90%
90%
90%
89%
90%
91%
90%
91%
90%
89%
90%
89%
90%
89%