Railway Power Solutions - Flipbook - Page 20
PAGE 20
RAILWAY DC/DC CONVERTERS (BOARD MOUNTING)
TEP 150WI
150 Watt
Model
¡ Shielded metal case with screw
terminals
¡ Ultra wide 4:1 input voltage ranges
¡ 9–36, 18–75, 43–160 VDC
¡ EN 50155 approval for railway
applications
¡ Very high efficiency up to 89%
¡ Constant current output characteristic for battery load applications
¡ Optional with input filter to meet
EN 55032 class B
¡ Wide Operating temperature
range: –40°C to +75°C
¡ Under voltage lock-out, overtemperature & reverse input protection
¡ Easy chassis and wall mounting
¡ 3-year product warranty
TEP 150-2412WI
TEP 150-2413WI
TEP 150-2415WI
TEP 150-2416WI
TEP 150-2418WI
TEP 150-4812WI
TEP 150-4813WI
TEP 150-4815WI
TEP 150-4816WI
TEP 150-4818WI
TEP 150-7212WI
TEP 150-7213WI
TEP 150-7215WI
TEP 150-7216WI
TEP 150-7218WI
Input Voltage
Range
9 – 36 VDC
(24 VDC nom.)
18 – 75 VDC
(48 VDC nom.)
43 – 160 VDC
(110 VDC nom.)
Output
Vnom
Imax
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
12 VDC
15 VDC
24 VDC
28 VDC
48 VDC
Efficiency
86%
86%
87%
87%
86%
88%
89%
89%
89%
88%
88%
89%
89%
89%
88%
Pinout
Pin
Function
1
+ Vin
Recommended Wire
14 – 16 AWG
2
+ Vin
14 – 16 AWG
3
– Vin
14 – 16 AWG
4
– Vin
14 – 16 AWG
5
Remote
14 – 24 AWG
6
+ Vout
14 – 16 AWG
7
– Vout
14 – 16 AWG
8
Trim
14 – 24 AWG
9
Trim
14 – 24 AWG
TEQ 160WIR
160 Watt
Model
Input Voltage
Range
TEQ 160-4812WIR
TEQ 160-4815WIR 19 – 75 VDC
TEQ 160-4816WIR (48 VDC nom.)
TEQ 160-4818WIR
TEQ 160-7212WIR
TEQ 160-7215WIR 43 – 160 VDC
TEQ 160-7216WIR (110 VDC nom.)
TEQ 160-7218WIR
¡ High power block with excellent
thermal convection
¡ Operating temperature –40°C to
+75°C without derating
¡ Increased shock & vibration
resistance
¡ Ultra wide 4:1 input voltage range
¡ EN 50155 approval for railway
applications
¡ Excellent efficiency up to 90%
¡ Input filter meet EN 55032, class A
¡ I/O insulation 1591 VAC
¡ Under voltage lock-out circuit
¡ Soft start
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
12’500 mA
10’000 mA
6300 mA
5400 mA
3200 mA
Output
Vnom
Imax
12 VDC
24 VDC
28 VDC
48 VDC
12 VDC
24 VDC
28 VDC
48 VDC
13’000 mA
6500 mA
5500 mA
3200 mA
15’000 mA
7500 mA
6500 mA
3800 mA
Efficiency
typ.
90%
90%
90%
90%
89%
89%
89%
89%
Pin Connection
Terminal Pin Function
1, 2
–Vin
3
NC
4
Recommended Wire
12 AWG
NC
On/Off Ctrl
14 – 18 AWG
5, 6
+Vin
12 AWG
7, 8
–Vout
12 AWG
9
–Sense*
14 – 18 AWG
10
+Sense*
14 – 18 AWG
11, 12
+Vout
12 AWG
* Sense line to be connected to the output either at the module or at the load
under regard of polarity.
• The current rating of the terminal block is 15 A/pole.
• Using 2 poles in parallel if the peak output current can exceed 15 A.
• Wire size shall be selected to withstand the peak output current (Iout max +
Current limitation).